● Reverse polarity protection;
● Short-circuit protection (IM8、IM12、IM18、IM30 DC type);
● Long-life & high reliability;
● Yellow Led indicates working status of sensor;
● Economical and easy to operate;
● Alternatives for mini switch and limit switch;
● Delay at power-up,guard against false pulse;
IM18 Series inductive sensor
Features of metal cylindrical proximity sensor:
● Reverse polarity protection;
● Short-circuit protection (IM8、IM12、IM18、IM30 DC type);
● Long-life & high reliability;
● Yellow Led indicates working status of sensor;
● Economical and easy to operate;
● Alternatives for mini switch and limit switch;
● Delay at power-up,guard against false pulse;
Proximity sensor |
|||||||
Model |
IM18B-05-DO |
IM18N-08-DO |
IM18B-05-NO |
IM18N-05-PO |
IM18B-08-NO |
IM18N-08-PO |
|
General parameters: |
|||||||
Installation method |
Flush style |
Non-flush |
Flush style |
Non-flush |
Flush style |
Non-flush |
|
Detection distance |
5mm±10% |
8mm±10% |
5mm±10% |
5mm±10% |
8mm±10% |
8mm±10% |
|
Return difference |
≤15% |
||||||
Set distance |
0~4mm |
0~6.4mm |
0~4 mm |
0~6.4 mm |
0~1.6 mm |
0~3.2 mm |
|
Mechanical/Electronic Parameters: |
|||||||
Operating voltage |
10-30VDC |
||||||
No-load current |
Max.5mA |
Max.8mA |
|||||
Voltage drop |
Max.2.5V |
Max.1.7V |
|||||
Operating frequency |
350Hz |
200Hz |
500Hz |
300 Hz |
500Hz |
300 Hz |
|
Indicator light |
Operation indicator yellow |
||||||
Function |
Short circuit protection,over voltage protection,reverse polarity protection |
||||||
Action mode |
Normally closed (DC) / normally open (DO) depending on the specific model |
Normally closed (NC)/Normally open (NO) depending on the specific model |
|||||
Control output |
Transistor output |
NPN |
PNP |
NPN |
PNP |
||
Wiring |
Direct outlet,DC2 wire,φ5,2*0.3 mm2,standard wire length: 2m; H3 model is connector type |
Direct outlet,DC3 wire,φ5,3*0.3 mm2,standard wire length: 2m; H3 model is connector type |
|||||
Protection rating |
IP67 |
||||||
Work temperature |
-25℃~75℃ (without freezing ) 35~95% RH |
||||||
Dimensions |
Please check the dimension drawing |
Please check the dimension drawing |
Proximity sensor |
|||||||
Model |
IM18B-08-NO |
IM18N-12-NO |
IM18B-05-AO |
IM18N-08-AO |
IM18B-05-DO-H3 |
IM18N-08-DO-H3 |
|
General parameters: |
|||||||
Installation method |
Flush style |
Non-flush |
Flush style |
Non-flush |
Flush style |
Non-flush |
|
Detection distance |
8mm±10% |
12mm±10% |
5mm±10% |
8mm±10% |
5mm±10% |
8mm±10% |
|
Return difference |
≤15% |
||||||
Set distance |
0~6.4mm |
0~9.6mm |
0~4 mm |
0~6.4 mm |
0~4mm |
0~6.4 mm |
|
Mechanical/Electronic Parameters: |
|||||||
Operating voltage |
10-30VDC |
24-240V AC |
10-30VDC |
||||
No-load current |
Max.5mA |
|
|||||
Voltage drop |
Max.1.3V |
Max.8V |
Max.2.5V |
||||
Operating frequency |
300Hz |
150Hz |
20Hz |
350Hz |
200Hz |
||
Indicator light |
Operation indicator yellow |
||||||
Function |
Short circuit protection,over voltage protection,reverse polarity protection |
over voltage protection |
Short circuit protection,over voltage protection,reverse polarity protection |
||||
Action mode |
Normally open |
Normally closed (AC)/Normally open(AO) depending on the specific model |
Normally closed (DC)/Normally open(DO) depending on the specific model |
||||
Control output |
Transistor output |
Single-stage SCR output |
Transistor output |
||||
Wiring |
Direct outlet,DC3 wire,φ5,3*0.3 mm2,standard wire length: 2m |
Direct outlet,AC2 wire,φ5,3*0.3 mm2,standard wire length: 2m; |
DC2 wire, Connector outlet,PL01、PL02、PL03 optional,standard wire length: 2m |
||||
Protection rating |
IP67 |
||||||
Work temperature |
-25℃~75℃ (without freezing ) 35~95% RH |
||||||
Dimensions |
Please check the dimension drawing |
Please check the dimension drawing |